The vibration of the vibrating disc is weak or too slow, and sporadic or irregular feeding may be caused by the following reasons:

1. The spring plate is broken, which requires replacing it with a new one and adjusting it to stabilize the machine.

2. The bottom plate is too thin.

3. Defects in the installation table, lack of hardness. If suspended on the equipment table, it will cause weak vibration. The thickness of the table must be at least 1-1/2 "to prevent vibration absorption. The cylindrical support feet must be equipped with triangular support plates.

4. The countertop is not level.

5. There are debris inside the vibrating disc.

6. The gap between the electromagnets is not appropriate.

7. The rapid pace of the machine caused the parts to slip off inside the vibrating disc.

8. There are too many materials.

9. The fluctuation of the power grid causes voltage instability.

10. Part issues: Irregular parts or oil content.

11. Improper adjustment of the vibration plate chassis

Return to the list

CONTACT US

Forrest focuses on the R&D, manufacturing, sales and service of automated assembly lines, testing equipment and other non-standard equipment.

TEL:+86-23-68234216

EMAIL:9898@forys-at.com

FAX:+86-23-61815295

ADD: No. 279, Yunfu Road, Water and Soil High-tech Industrial Park, Liangjiang New District (Beibei District), Chongqing

MESSAGE

Username used for comment:
客户留言
Description:
验证码
Online customer service
Customer service hotline
023-61972695 023-61972695
Service time:
9:00 - 18:00
Customer service group:
Customer
Business License